Image Barcode Scan Engine
Feature
The decode board provides a ZIF 12-pin connector to connect to a 0.5 mm × 12 position FFC/FPC cable.
The scan engine has one normal power state, the run state, and three low-power states (idle, standby and sleep) and there are five control parameters.
Item | Description |
Inputvoltage | 3.3 VDC±5% |
Scanning current |
Typical: 360 mA |
Maximum: 386 mA | |
Standby current | 8 mA |
Image size | 752 × 480 pixels |
Scanning angles | ±60°, ±40°, ±42° (Skew, Pitch, Roll) |
Decode capability |
1D: UPC-A, UPC-E, UPC-E1, EAN-13, EAN-8, ISBN (Bookland EAN), ISSN, Code 39, Code 39 full ASCII, Code 32, Trioptic Code 39, Interleaved 2 of 5, Industrial 2of 5, Matrix 2 of 5, Codabar (NW7), Code 128, ISBT 128, Code 93, Code 11 (USD-8), MSI/Plessey, UK/Plessey, UCC/EAN 128, China Post, China Finance, GS1 DataBar (formerly RSS) variants |
2D: PDF417, MicroPDF417, QR Code, DataMatrix, Han Xin Code, Aztec Code |
|
Indicator Interface | To control external Beeper and LED |
Interface supported | RS-232 (3.3V TTL-level) |
Scan mode | Good-Read off, Momentary, Alternate, Continuous, Time-Out Off, Host |
Dimensions |
Image module: 10.0 mm × 20.0 mm × 16.2 mm (Height × Width × Depth) |
Decode board: 23.3 mm × 38.4 mm × 7.9 mm (Height × Width × Depth) | |
Weight |
Image module: 8 g |
Decode board: 7 g | |
Cable | Tapered 12-pin flex strip (12 × 0.5 mm) |
Min. element width | 3.5 mil, 1 mil = 0.0254 mm |
Decoding depth |
3.5mil Code128 ( 9 chars): 1.5cm – 3.5cm 5mil Code39 (20 chars): 0.8cm – 5.5cm 13mil UPC (12 chars): 0.7cm – 16.5cm 20mil Code39 ( 5 chars): 3.5cm – 21.0cm 6.7mil PDF417 (20 chars): 0.0cm – 7.5cm 10 mil DM (20 chars): 0.0cm – 11.5cm 20 mil QR (20 chars): 0.0cm – 19.5cm |
Temperature | Operating: -10 °C to 60 °C (-4 °F to 140 °F) |
Storage: -40 °C to 70 °C (-40 °F to 158 °F) | |
Humidity | 5% to 90% (non-condensing) |
Programming method |
Manual (scanning special barcodes in sequence) Sending commands via RS-232 interface |
Firmware upgrade | Online |
Safety |
Laser Safety: EN60825-1, Class 1 |
EMC: EN 55022, EN 55024 | |
ESD protection: EN 55024 (IEC 61000-4-2, contact discharge: ±2kV, air discharge: ±8kV), IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-11 |