Conductor: O. F. C solid copperΦ0.50 mm
Insulation: HDPEΦ0.93mm
Shield: Aluminium mylar+tinned copper wire 16/6/0.12 (TC)
Jacket: Flame retardant grey PVC Nom O. D. 6.40mm
STANDARDl YD/T 1019-2001
APPLICATION: The horizontal twisted shield pair cable for digital communication APPLICATION, is mainly used for the wiring between telecom lead-outs of work area and floor distributor comprehensive system, as well as the wiring between the user telecom lead-outs and floor distributor comprehensive system, it meets the requirements lf 155MHz data communication. Its dualshield protection brings entire channel higher anti-disturbance ability, so as to ensure correct data transmittance ever under the environment of high electromagnetic disturbance. It applies to the environment such as army, hospital, bank and financial system that have special requirements fo high-preformance transmittance. With standard wiring length 90m, it is connected in T568A or T568B manner. The end employs shield and grounded fittings, so as to ensuer channel to transmit normally under shield protection. Coded according to ANSI/TIA/EIA-568-B color code.
155Mbps ATM, 100Mbps TP-PMD, 100Mbps Ethernet(100BASE-T) and other systems below 622Mbps
1000Mbps Ethernet 4 Mbps and 16 Mbps Token Ring Network 10Mbps Ethernet
Insulation: HDPEΦ0.93mm
Shield: Aluminium mylar+tinned copper wire 16/6/0.12 (TC)
Jacket: Flame retardant grey PVC Nom O. D. 6.40mm
STANDARDl YD/T 1019-2001
APPLICATION: The horizontal twisted shield pair cable for digital communication APPLICATION, is mainly used for the wiring between telecom lead-outs of work area and floor distributor comprehensive system, as well as the wiring between the user telecom lead-outs and floor distributor comprehensive system, it meets the requirements lf 155MHz data communication. Its dualshield protection brings entire channel higher anti-disturbance ability, so as to ensure correct data transmittance ever under the environment of high electromagnetic disturbance. It applies to the environment such as army, hospital, bank and financial system that have special requirements fo high-preformance transmittance. With standard wiring length 90m, it is connected in T568A or T568B manner. The end employs shield and grounded fittings, so as to ensuer channel to transmit normally under shield protection. Coded according to ANSI/TIA/EIA-568-B color code.
155Mbps ATM, 100Mbps TP-PMD, 100Mbps Ethernet(100BASE-T) and other systems below 622Mbps
1000Mbps Ethernet 4 Mbps and 16 Mbps Token Ring Network 10Mbps Ethernet